Articles / 3 min read
Clinker in a coal boiler or furnace: why ash fuses and how to stop it
Clinker is coal ash that has melted and set into hard glassy lumps on or above the grate. Plants that went back to coal this year often meet it in the first few weeks: the lumps cover the air holes, the fire runs uneven and the boiler loses output.

Why ash fuses
Ash is a mix of minerals that melts over a range of temperatures. When the fuel bed runs hotter than the ash can stand, it turns sticky and sets into clinker as it cools. Blocked air makes some places hotter, which makes more clinker, and the operator who opens the dampers makes it worse.
Four things combine: ash that melts easily, a lot of ash, uneven air and a bed that runs too hot. Iron, calcium, sodium and sulphur compounds lower the melting point, and the sheet cannot tell you that. A lab can, with the ash fusion test, which reports the temperatures at which a cone of the ash deforms, softens, becomes hemispherical and flows. Ask for it and for an ash analysis with every grate-boiler lot, not only heat and sulphur. Fines pack the bed and restrict air, and swings in moisture change the bed temperature hour to hour.
Symptom, likely cause, first check
Work down from the cheapest check. Most clinker yields to a change in operation before it needs a change in coal.
| What you see | Likely cause | First check |
|---|---|---|
| Hard lumps stuck to grate bars | Bed too hot or ash melts low | Lower bed temperature, open more primary air, ask for the ash fusion test |
| Fire dark in patches, bright in others | Uneven coal size or fines in the feed | Screen the coal and reduce the fines share |
| Clinker only on some days | Moisture or ash changes between lots | Compare lab reports and delivery dates |
| Clinker grows every shift | Grate not cleaned often enough | Shorten the cleaning interval, check grate speed |
| Clinker after a switch from gas | Grate and air set for another fuel | Set air, bed depth and coal size in a commissioning run |
| Steam falls with the same feed; air pressure under the grate rises | Air holes blocked by old clinker | Clear the holes, look for worn bars |

Fixes on the boiler, then the coal
Keep bed depth steady and not too deep, hold primary air in range because too little lets the bed overheat, clean the grate on schedule, screen out oversize and dust, and keep coal dry. If clinker persists the coal is the next suspect. Sor Range and Chamalang lump leave less ash per tonne, which is no promise against fusion, so try a small trial of cleaner coal and compare clinker over a week. The article on how to read a coal analysis explains each line of a report. A hand-fired furnace gives the most control and least consistency; a chain or travelling grate shows a change of coal quickly as clinker; a fluidised bed holds the bed below the point where most ash melts. When you change coal, run the new fuel at part load first.
| How often | Task |
|---|---|
| Every shift | Clean the grate and remove ash and clinker on schedule; check the fire is even across the grate |
| Every shift | Check feed size: screen out dust and oversize pieces |
| Every delivery | Weigh the truck, take a sample, record the lot with heat, ash and moisture figures |
| Weekly | Look for blocked air holes and worn bars |
| Monthly | Send a sample to a lab for ash analysis and fusion temperatures |
Breaking it out safely
Clinker holds heat long after the fire has died back. Let the boiler cool as the maker advises, use long tools, heat-proof gloves and eye protection, keep clear of the door when you open it, and never put water on hot clinker because the steam burns. The article on coal ash uses and disposal covers where it goes afterwards.
Questions people ask
What is an ash fusion test?
A lab test that reports the temperatures at which an ash cone deforms, softens, becomes hemispherical and flows. Ask for it when buying coal for a grate boiler.
Which coal has the least ash?
On our sheet Sor Range has the lowest typical ash, then Chamalang lump. Check the lab report for your lot.
Prices are indicative, per tonne, excluding sales tax, and change week to week. See today's sheet or ask us for a confirmed price.