Articles / 2 min read
ADB and ARB on a coal report: what the difference means
Two lab reports for the same coal can show heat values a few hundred kcal apart and both be right, because one is on an air dried basis (ADB) and the other as received (ARB). ARB is the coal as it arrives with all its water; ADB keeps only the water locked inside the coal, so every ADB figure for heat, ash and sulphur is higher.

The conversion, with one coal
Total moisture is the water in the coal as received. Inherent moisture is what stays after air drying. The gap between them is surface water you pay freight on and burn off in the furnace.
Take a coal reported at 6,300 kcal/kg ADB with 4% inherent moisture. If the truck arrives at 8% total moisture, the as received heat is 6,300 x (100 - 8) / (100 - 4), about 6,040 kcal/kg, roughly 4% less in every tonne you pay for. Ash and sulphur scale by the same factor. Wetter coal widens the gap, and fines left in the rain can lose several hundred kcal between the paper and the kiln.
- 4% total moisture6,300 kcal/kg as received
- 6% total moisture6,169 kcal/kg as received
- 8% total moisture6,038 kcal/kg as received
- 10% total moisture5,906 kcal/kg as received
- 12% total moisture5,775 kcal/kg as received
ARB = 6,300 x (100 - total moisture) / (100 - 4).
Comparing two offers
Offer A is 6,300 kcal/kg ADB with 4% inherent and 8% total moisture on arrival, at the Chamalang lump price on our sheet, Rs 40,000 a tonne ex-Quetta. Offer B is 6,000 kcal/kg ARB at the Duki lump price, Rs 38,750. The prices are borrowed from the sheet only to keep the numbers realistic.
Offer A reads 6,300 but is 6,038 kcal/kg as received. Cost per million kcal comes to Rs 6,625 for A and Rs 6,458 for B. Compare on that figure, not on the headline kcal. The coal price comparison calculator does the same sum.
Four bases and gross against net
A full report can show four bases side by side: ARB (as received), ADB (air dried), DB (dry, all water removed) and DAF (dry ash free). DB and DAF are for comparing coals from different mines and judging rank, not for what goes into a boiler or bhatta.
Heat also comes gross (GCV, GAR) or net (NCV, NAR). Gross counts the heat recovered when the water vapour in flue gas condenses, which a boiler stack never gets back, so net is lower. Most labs report ADB first because air drying makes results repeatable between labs. For a buyer, that means bringing the report to the delivered state yourself: you need inherent moisture from the report and total moisture from a sample taken at your gate. The coal analysis converter does it. If total moisture is missing from the report, ask for it before comparing anything.
Questions people ask
Is GAR the same as ARB?
No. GAR is gross heat on an as received basis. ARB names only the basis, so check whether a figure is gross or net as well.
Prices are indicative, per tonne, excluding sales tax, and change week to week. See today's sheet or ask us for a confirmed price.



